Turbo Chef Technologies 3240 manual 3 0 T RO U B L E S H O OT I N G

Models: 3240

1 92
Download 92 pages 62.2 Kb
Page 52
Image 52
3 0 T RO U B L E S H O OT I N G

3 0 T RO U B L E S H O OT I N G

F8: High Limit Tripped

F10: Air Switch Fault

This fault is displayed if the high limit switch trips. The switch trips when the high limit probe reads approximately 600°F (315.5°C).

The fault is cleared from the display when the high limit switch is manually reset.

F9: Belt Fault

This fault occurs if the conveyor belt fails to start.

The fault is cleared from the display if the conveyor belt starts when initiating cooking.

This fault occurs if the air pressure switch on the burner fails to close when the burner circuit is energized.

The fault is cleared from the display when the air pressure switch closes after the burner circuit is energized.

Fault Code and Description

When Active

 

 

 

Refer to...

 

 

 

 

 

 

 

Warming

Idle

Cooking

Test

 

 

 

 

 

 

 

F1: Blower Failure

α

α

α

α

Page 31

 

 

 

 

 

 

 

 

 

 

F2: Low Temp During Cook

 

 

α

 

Page 32

 

 

 

 

 

 

 

 

 

 

F3: Flameout

α

α

α

α

Page 34

 

 

 

 

 

 

 

 

 

 

F4: Emergency Stop

α

α

α

α

N/A

 

 

 

 

 

 

 

 

 

 

F5: CC Over Temp

 

 

α

α

Page 36

 

 

 

 

 

 

 

 

 

 

F6: EC Over Temp

α

α

α

α

Page 37

 

 

 

 

 

 

 

 

 

 

F7: RTD Failure

α

α

α

α

Page 38

 

 

 

 

 

 

 

 

 

 

F8: High Limit Tripped

 

 

α

α

Page 38

 

 

 

 

 

 

 

 

 

 

F9: Belt Fault

α

α

α

 

Page 39

 

 

 

 

 

 

 

 

 

 

F10: Air Switch Fault

α

α

α

α

Page 40

 

 

 

 

 

 

 

 

 

 

Figure 36: Fault Code Table

NOTE: All fault codes, except F2 and F9 will terminate cooking upon discovery. Any fault that occurs will be logged in the in the fault count log (page 16), except F6.

Page 52
Image 52
Turbo Chef Technologies 3240 manual 3 0 T RO U B L E S H O OT I N G