3 0 T RO U B L E S H O OT I N G
F8: High Limit Tripped | F10: Air Switch Fault |
This fault is displayed if the high limit switch trips. The switch trips when the high limit probe reads approximately 600°F (315.5°C).
The fault is cleared from the display when the high limit switch is manually reset.
F9: Belt Fault
This fault occurs if the conveyor belt fails to start.
The fault is cleared from the display if the conveyor belt starts when initiating cooking.
This fault occurs if the air pressure switch on the burner fails to close when the burner circuit is energized.
The fault is cleared from the display when the air pressure switch closes after the burner circuit is energized.
Fault Code and Description | When Active |
|
|
| Refer to... |
|
|
|
|
|
|
| Warming | Idle | Cooking | Test |
|
|
|
|
|
|
|
F1: Blower Failure | α | α | α | α | Page 31 |
|
|
|
| ||
|
|
|
|
|
|
F2: Low Temp During Cook |
|
| α |
| Page 32 |
|
|
|
| ||
|
|
|
|
|
|
F3: Flameout | α | α | α | α | Page 34 |
|
|
|
| ||
|
|
|
|
|
|
F4: Emergency Stop | α | α | α | α | N/A |
|
|
|
| ||
|
|
|
|
|
|
F5: CC Over Temp |
|
| α | α | Page 36 |
|
|
|
| ||
|
|
|
|
|
|
F6: EC Over Temp | α | α | α | α | Page 37 |
|
|
|
| ||
|
|
|
|
|
|
F7: RTD Failure | α | α | α | α | Page 38 |
|
|
|
| ||
|
|
|
|
|
|
F8: High Limit Tripped |
|
| α | α | Page 38 |
|
|
|
| ||
|
|
|
|
|
|
F9: Belt Fault | α | α | α |
| Page 39 |
|
|
|
| ||
|
|
|
|
|
|
F10: Air Switch Fault | α | α | α | α | Page 40 |
|
|
|
| ||
|
|
|
|
|
|
Figure 36: Fault Code Table
NOTE: All fault codes, except F2 and F9 will terminate cooking upon discovery. Any fault that occurs will be logged in the in the fault count log (page 16), except F6.