4 Software Operation

enter an invalid time, the display will go back to the previous valid time.)

The Span field displays the 15-minute span that the time you speci- fied is within, and the error fields display counts of the errors that occurred during that 15-minute time span.

3.To view counts for the errors listed in the bottom portion of the screen for a specific channel, tab to the Channel # field in the upper portion of the frame, type a channel number, and then press Enter.

The Channel # and error counts in the lower portion of the screen are updated for the channel number you specified.

4.To clear the counts for the channel you are viewing, tab to the [Clear] button and press Enter. This also clears the 24-hour counts for the channel.

To clear counts for all channels, tab to the [Clear All] button and press Enter. This also clears the 24-hour counts for all channels.

A prompt appears asking you to confirm the clear.

5.Type y and press Enter. The error counts clear.

To View Low-Speed Errors in 24-Hour Histories

The Low Speed Errors-24 hr. screen updates every 15 minutes, displaying error counts for two time periods: from Midnight the current day to the end of the last completed 15-minute period (Current View) and from Midnight the previous day to one second before Midnight the current day (Previous View).

When you select either view in the View field, the upper portion of the screen displays Errored Seconds (ES), Errored Seconds Ratio (ESR), Se- verely Errored Seconds (SES), and Severely Errored Seconds Ratio (SESR) for all channels. By typing a channel number in the Channel # field, you can view the CV. LOSS, and AISS error counts for each channel in the lower portion of the screen. When finished viewing the error counts, you can either clear both periods for the channel you are viewing or clear them for all channels.

NOTE

During the first 15-minute period of the day (between 00:00:00 and 00:14:59) no Current counts are shown. However, you still can see error counts during this period by going to the Low Speed Errors-15 min. screen.