4 Software Operation

MIX 56 User Manual

Step Action

1.From the Directory screen, press 6 to select High Speed Configura- tion, then Enter.

The High Speed Configuration screen appears.

MIX 56 by Telect

MIX 56

Directory (Ctrl+D)

 

 

Help (?)

 

High Speed Configuration

 

 

------------------------

 

 

Name: High Speed

 

 

Clock Source: DS3 Loop Timing

 

 

Mode: M13

 

 

Optional C-bit LAPD Information

 

Local

-------------------------------

 

Remote

 

Equipment ID: ---------------------------------

-------------------------------

 

 

Location ID:

 

 

Frame ID:

 

 

Unit ID:

 

 

Facility ID - Local:

Facility ID - Remote:

[Apply]

2.In the Name field, type a name for the DS3 circuit (up to 16 charac- ters) and press Enter.

3.Tab to the Clock Source field, select a clock source by pressing the spacebar to toggle between DS3 Loop Timing and Internal, and then press Enter.

DS3 Loop Timing—Timing is recovered from the incoming DS3 signal.

Internal—Timing is generated by the onboard Stratum 4 clock.

NOTE

In DS3 networks, one network element provides master timing, while the other one recovers timing from the incoming DS3 signal.

4.Tab to the Mode field, select a DS3 mode by pressing the spacebar to toggle between M13 and C-bit, and then press Enter.

4-20

Telect, Inc. 122188-10 A0

Page 66
Image 66
Telect MIX 56 user manual Name High Speed