MIX 56 User Manual | 4 Software Operation |
When test mode “T1/E1 Test on High Speed Line” is selected then you also specify:
1.Which channel of the muxed DS3 signal to insert the test pattern on.
2.Whether to use a framed test signal or not.
3.What frame format to use if using a framed test signal.
4.What remote alarm format to use if T1 line and using a framed test signal
When test mode “Unframed Test on Low Speed Line” is selected then you also specify which low speed channel to do the test on.
To Specify a BER Test
Step Action
1.From the Directory screen, press 20 to select “BER Testing”, then press enter. The “BER Testing” screen appears:
MIX 56 by Telect | MIX 56 | Directory (CTRL+D) |
|
| Help (?) |
| BER Testing |
|
|
| |
Mode: T1/E1 Test on High Speed Line | ||
Pattern: Disabled |
| |
|
| Receiving Pattern: None |
Low Speed Channel #: | 1 | Line Type: T1 |
Framed Signal: | Yes |
|
Frame Format: | ESF |
|
RAI: | FS Bit |
|
[Apply]
2.In the “Mode” field select the mode by pressing the spacebar to tog- gle between “CBit DS3 Test on High Speed Line”, “Unframed Test on Low Speed Line”, or “T1/E1 Test on High Speed Line” and then pressing Enter.