MIX 56 User Manual

4 Software Operation

When test mode “T1/E1 Test on High Speed Line” is selected then you also specify:

1.Which channel of the muxed DS3 signal to insert the test pattern on.

2.Whether to use a framed test signal or not.

3.What frame format to use if using a framed test signal.

4.What remote alarm format to use if T1 line and using a framed test signal

When test mode “Unframed Test on Low Speed Line” is selected then you also specify which low speed channel to do the test on.

To Specify a BER Test

Step Action

1.From the Directory screen, press 20 to select “BER Testing”, then press enter. The “BER Testing” screen appears:

MIX 56 by Telect

MIX 56

Directory (CTRL+D)

 

 

Help (?)

 

BER Testing

 

 

-----------

 

Mode: T1/E1 Test on High Speed Line

Pattern: Disabled

 

 

 

Receiving Pattern: None

Low Speed Channel #:

1

Line Type: T1

Framed Signal:

Yes

 

Frame Format:

ESF

 

RAI:

FS Bit

 

[Apply]

2.In the “Mode” field select the mode by pressing the spacebar to tog- gle between “CBit DS3 Test on High Speed Line”, “Unframed Test on Low Speed Line”, or “T1/E1 Test on High Speed Line” and then pressing Enter.

122188-10 A0

Telect, Inc.

4-51

Page 97
Image 97
Telect MIX 56 user manual To Specify a BER Test