MIX 56 User Manual | 4 Software Operation |
NOTE
The remote setting is controlling the MIX 56 at the other end of the DS3 link. For this to work, the DS3 mode must be set to
A remote control link will log the user out so the user will have to log into the remote MIX 56. [On a remote control link, the System Name at the cen- ter of the page heading will have a “(Remote)” after it.]
Specifying System Interface Settings
In the System Interfaces screen, you can specify the Craft port baud rate, SNMP community names, and Ethernet addresses. You can also ping other systems on the network.
NOTE
Before using the Ethernet port, you must connect to the local Craft inter- face through the Craft port and set the system’s IP, Subnet Mask, and Gate- way addresses in the System Interfaces screen.
From the Directory screen, type 9 to select System Interfaces and press En- ter. The System Interfaces screen appears.
MIX 56 by Telect |
| MIX 56 |
|
| Directory (Ctrl+D) | ||
|
|
|
|
|
|
| Help (?) |
|
| System Interfaces |
|
|
|
| |
|
|
|
|
|
| ||
| Serial Port |
|
| Ethernet |
|
| |
Baud Rate: |
| IP Address: | |||||
115200 |
| 10. | 60.125.250 | ||||
Modem Detect: Disabled |
| Subnet Mask: | 255.255. | 0. | 0 | ||
| SNMP Community Names | Gateway: | 10. | 60.254.254 | |||
| Trap 1: | 0. | 0. | 0. | 0 | ||
| Trap 2: | 0. | 0. | 0. | 0 | ||
Read: public |
| Trap 3: | 0. | 0. | 0. | 0 | |
Write: private |
| Trap 4: | 0. | 0. | 0. | 0 | |
Trap: |
|
| rap 5: | 0. | 0. | 0. | 0 |
SNMP Event Traps: Enabled |
| Trap 6: | 0. | 0. | 0. | 0 | |
| Duplex: Half |
|
|
| |||
Ping Address: | 0. 0. 0. | 0 |
|
|
| ||
|
|
| [Apply] | ||||
| [Ping] |
|
|
|
|
Ping Response:
To Change the Baud Rate
Step Action
1.In the Baud Rate field, press the spacebar to toggle between baud rates, and then press Enter.
If you select a different baud rate, the screen becomes unreadable.