MIX 56 User Manual1 Descriptions
LED Panel
| CRAFT |
CRT MJR MNR MAINT | HS LS ACO |
| ACO/LAMP |
Critical |
|
Major | High Speed |
Minor | Low Speed |
Maintenance | Alarm Cutoff |
| (ACO) |
LED | Status | Definition | |
|
|
| |
| Red | One or more critical alarms. (Two or more DSIs and/ | |
Critical | or DS3 service affecting conditions.) | ||
| |||
|
| ||
| Unlit | No critical alarms | |
|
|
| |
| Red | One or more major alarms. (DS1 or DS3 service im- | |
Major | pacting condition.) | ||
| |||
|
| ||
| Unlit | No major alarms | |
|
|
| |
| Yellow | One or more minor alarms. Service processing and | |
Minor | traffic unaffected. | ||
| |||
|
| ||
| Unlit | No minor alarms | |
|
|
| |
| Yellow | Diagnostic tests are being performed; at least one | |
Maintenance | circuit is out of service | ||
| |||
|
| ||
| Unlit | No diagnostic tests are being performed | |
|
|
| |
| Red | Receiving alarm indication signal (AIS) or experienc- | |
| ing loss of signal (LOS) or out of frame (OOF) signal | ||
|
| ||
|
|
| |
High Speed | Yellow | Receiving remote alarm indication (RAI) | |
|
| ||
| Green | Operating normally | |
|
|
| |
| Unlit | Out of service or no power | |
|
|
| |
| Red | Receiving AIS or experiencing LOS | |
|
|
| |
Low Speed | Green | Operating normally | |
|
|
| |
| Unlit | Out of service or no power | |
|
|
| |
Alarm Cutoff (ACO) | Yellow | ACO is engaged | |
|
| ||
Unlit | ACO is not engaged | ||
| |||
|
|
|
NOTE
When a MIX 56 system used as a multiplexer is operating normally, the High Speed and Low Speed LEDs on the LED panel and the active M13 card LED are all green. If the system is redundant, the standby card LED is orange. Any LED configuration other than this indicates the system is not operating normally.
Telect, Inc. |