4 Software Operation

MIX 56 User Manual

2.To log out, type y and press Enter.

The screen displays your user ID (if security is on) and the time you logged out.

CONFIGURING MIX 56

Each MIX 56 chassis houses two independent systems. When you access the Craft interface, whether through an Ethernet port on the rear or a Craft port on the front, your settings and configurations pertain only to the sys- tem on the same side of the chassis as the port to which you connected. The system on the other side is completely unaffected.

Specifying System Settings & M13 Card Functions

In the System Settings screen, you can specify a system’s general settings and reset either M13 card. General settings include the date and time, the active M13 card, and times for the Alarm Cutoff and inactivity timer. The System Settings screen also displays the system’s chassis, alarm card, and software versions.

To Specify a System’s Settings

Step Action

1.From the Directory screen, press 5 to select System Settings, then Enter. The System Settings screen appears:

MIX 56 by Telect

MIX 56

Directory (Ctrl+D)

 

 

 

 

Help (?)

 

System Settings

 

 

 

---------------

 

 

System Name: MIX 56

 

Active Card:

2

 

System Location:

 

Redundant M13 Cards:

Yes

min.

Contact Person:

 

ACO Time:

15

(dd/mon/yy) Date: 08/Jul/02

 

Inactivity Timeout:

15

min.

(hh:mm:ss) Time: 10:56:03

Loopback Permission: No

AIS Terminates LB: Yes (as per T1.403)

Reset: Standby Card

Low Speed Type: T1

 

Control: Local

LS Remote LB Dir: DS3

 

Telnet TL1: No

Chassis Version: B0

 

Alarm Card Version: A1

 

 

Card 1

Card 2

M13 Board Version:

------------

---------

302950-A1

302950-A1

Firmware Version:

2.03

2.03

CPLD Version:

A1

A1

Serial Number:

0005C40000AA

0005C40000E5

4-14

Telect, Inc. 122188-10 A0

Page 60
Image 60
Telect MIX 56 user manual Configuring MIX, Specifying System Settings & M13 Card Functions, To Specify a System’s Settings