1 Descriptions

MIX 56 User Manual

Features

DSX and M13 in one chassis

Two fully independent systems per chassis, each with 28 DSX jacks and up to two M13 cards, in a 5.25 inch (3 RU) rack space

Mounts in 19 inch (48.3 cm) or 23 inch (58.4 cm) WECO-spaced or EIA-spaced racks

Multiplexes 28 DS1 or 21 E1 signals into one DS3 signal and demulti- plexes a DS3 signal into 28 DS1 or 21 E1 signals

1:1 redundancy with second M13 card

Processor switching occurs in less than 50 ms

LED status indicators and tracer lamps on front panel

DSX jacks, tracer lamps, and alarm boards are field replaceable and M13 cards are hot-swappable, all from the front of the chassis

Form-C critical, major, and minor external alarm contacts

Remote provisioning and monitoring through SNMP or two concurrent Telnet sessions

Separate alarm and event logs are rotating logs of up to 99 entries each

Selectable alarm thresholds

DS1 and DS3 loopback capabilities

BER Testing

DS3 signal format selectable between C-bit or M13 mode

C-Bit Remote Control to the MIX 56 at the other end of the DS3 link

DS1 line coding individually selectable between AMI or B8ZS for T1 and AMI or HDB3 for E1

Adjustable DS1 transmit line build out (LBO) for each channel

Automatic DS3 LBO

DS3 transmit clock source either recovered from DS3 receive signal or by internal oscillator

Universal voltages: 20Vdc to 60Vdc

Three levels of user login security

Part Numbers

Part No.

 

Configuration

 

 

 

747-0000-2448

56

DSX Jacks, No M13 Cards

 

 

 

747-1103-2801

56

DSX Jacks, Two M13 Cards

 

 

 

747-1103-5601

56

DSX Jacks, Four M13 Cards

 

 

 

1-2

Telect, Inc. 122188-10 A0

Page 12
Image 12