4 Software Operation | MIX 56 User Manual |
| Major: | |
| speed line or cause performance issues on the | |
| Minor: conditions that do not affect service. | |
| While some conditions trigger alarms automatically, you can set thresholds | |
| for other conditions in the Alarm Thresholds screen. The following table | |
| describes the Critical, Major, and Minor alarm conditions and identifies | |
| which have | |
|
|
|
Critical | Two or more low speed lines are in LOS | |
|
|
|
| DS3 receiving RAI. | |
|
|
|
| DS3 LOS. | |
|
|
|
Major | DS3 OOF. | |
|
|
|
| DS3 receiving AIS. | |
|
|
|
| DS3 SES and ES | |
|
|
|
| DS1 receiving AIS. | |
|
|
|
| DS1 LOS. | |
|
|
|
| DS1 SES and ES | |
|
|
|
Minor | System Settings configured for Redundant M13 Cards, but only 1, M13 Card installed. | |
|
|
|
| System Settings configured for No Redundant M13 Cards, but have 2, M13 Cards installed. | |
|
|
|
| Standby card failure | |
|
|
|
| Standby card in critical alarm | |
|
|
|
| Active and standby cards have different software versions | |
|
|
|
| Locked out of protection switching* | |
|
|
|
| Loss of | |
|
|
|
| Maintenance minor alarm (Loopback, BER testing, Programming Standby) | |
|
|
|
*Locked out for 10 min. after any automatic switch. Locked out for 12 hrs after third switch within one hour.
Viewing Alarms
You can view alarms in two ways: Current Alarms or Alarm Log history.
You can view the alarms for either the active card or the standby card.
To View Current Alarms
The Current Alarms screen displays the date and time the alarm started, de- tails about the alarm, the time remaining on the Alarm Cutoff (ACO) timer (if it has been engaged), and where you can engage and disengage the ACO. Engaging the ACO closes the external alarm contacts, turning them off, while disengaging the ACO turns external alarms back on.
Telect, Inc. |