Telect MIX 56 user manual 4-53, Type “y” and Enter to perform the selected BER test

Models: MIX 56

1 124
Download 124 pages 12.01 Kb
Page 99
Image 99

MIX 56 User Manual

4 Software Operation

7.Tab to the “RAI” field and toggle between the available options by pressing the spacebar and then pressing Enter. This field only ap- plies to a T1 signal and selects the remote alarm format (remote alarm indication, RAI). The available options are bit2 equals zero in every channel (Bit 2=0) and FS bit of frame 12 of the framed sig- nal (FS Bit).

NOTE

This field is only available in the “T1/E1 Test on High Speed Line” mode.

8.To apply the BER test selected, tab to the [Apply] button and press enter. A prompt will appear telling you that this action will cause a continuous traffic interruption and ask if you want to continue.

If a Low Speed Channel is selected that is either disabled or un- available, then the [Apply] button is not enabled.

9.Type “y” and Enter to perform the selected BER test.

122188-10 A0

Telect, Inc.

4-53

Page 99
Image 99
Telect MIX 56 user manual 4-53, Type “y” and Enter to perform the selected BER test