4 Software Operation | MIX 56 User Manual |
Step Action
1.From the Directory screen, press 17 to select Alarm Log, then En- ter.
The Alarm Log screen appears.
MIX 56 by Telect |
|
| system 2 | Directory (Ctrl+D) | ||
|
|
|
|
|
| Help (?) |
|
|
|
|
| Alarm Log - Active |
|
Card Select: Active |
|
|
| |||
|
|
|
| |||
# | Date | Time | Alarm Details |
| ||
1 | 22/Oct/03 | 07:37:35 | Mnr | System,multiple low speed failures,on | ||
2 | 22/Oct/03 | 07:37:35 | Crt |
| ||
3 | 22/Oct/03 | 07:37:35 | Mnr |
| ||
4 | 22/Oct/03 | 07:37:18 | Crt | 24 | hr. SES HS threshold crossed,off | |
5 | 22/Oct/03 | 07:37:18 | Mnr | 24 | hr. ES HS threshold crossed,off | |
6 | 22/Oct/03 | 07:37:18 | Crt | 15 | min. SES HS threshold crossed,off | |
7 | 22/Oct/03 | 07:37:18 | Crt | 15 | min. ES HS threshold crossed,off | |
8 | 22/Oct/03 | 07:36:52 | Crt | System,standby card detected critical alarm,off | ||
9 | 22/Oct/03 | 07:36:51 | Crt |
| ||
10 | 22/Oct/03 | 07:30:00 | Mnr | 24 | hr. ES HS threshold crossed,on | |
11 | 22/Oct/03 07:29:59 Mnr | 24 | hr. SES LS threshold crossed,on | |||
|
|
|
|
| [Next] | [Previous] [Clear] |
2.Tab to “Card Select” and press the space bar to toggle between “Active” and “Standby”. Press Enter.
3.To view the next 11 entries, tab to the [Next] button and press Enter.
4.To view the previous 11 entries, tab to the [Previous] button and press Enter.
5.To clear the entire log, tab to the [Clear] button and press Enter. A prompt appears asking you to confirm the clear. Type y and press Enter. The Alarm Log clears.
Setting Alarm Thresholds
In the Alarm Thresholds screen, you can specify some of the conditions that trigger and clear the system alarms. Each threshold is counted in one second increments, and for most alarms, you can set one threshold to trig- ger the alarm and another to clear it (ES and SES alarms do not need Alarm Off thresholds because they clear automatically when the time span on which they are based passes).
Telect, Inc. |