Telect MIX 56 user manual Setting Alarm Thresholds, 4-42, Step Action

Models: MIX 56

1 124
Download 124 pages 12.01 Kb
Page 88
Image 88
Setting Alarm Thresholds

4 Software Operation

MIX 56 User Manual

Step Action

1.From the Directory screen, press 17 to select Alarm Log, then En- ter.

The Alarm Log screen appears.

MIX 56 by Telect

 

 

system 2

Directory (Ctrl+D)

 

 

 

 

 

 

Help (?)

 

 

 

 

 

Alarm Log - Active

 

Card Select: Active

 

 

------------------

 

 

 

 

 

#

Date

Time

Alarm Details

 

--

---------

--------

----- ---------------------------------------------------

1

22/Oct/03

07:37:35

Mnr

System,multiple low speed failures,on

2

22/Oct/03

07:37:35

Crt

LS-02(Low Speed 02),Rx AIS,off

 

3

22/Oct/03

07:37:35

Mnr

LS-02(Low Speed 02),LOS,on

 

4

22/Oct/03

07:37:18

Crt

24

hr. SES HS threshold crossed,off

5

22/Oct/03

07:37:18

Mnr

24

hr. ES HS threshold crossed,off

6

22/Oct/03

07:37:18

Crt

15

min. SES HS threshold crossed,off

7

22/Oct/03

07:37:18

Crt

15

min. ES HS threshold crossed,off

8

22/Oct/03

07:36:52

Crt

System,standby card detected critical alarm,off

9

22/Oct/03

07:36:51

Crt

HS-01(High Speed),LOS,off

 

10

22/Oct/03

07:30:00

Mnr

24

hr. ES HS threshold crossed,on

11

22/Oct/03 07:29:59 Mnr

24

hr. SES LS threshold crossed,on

 

 

 

 

 

[Next]

[Previous] [Clear]

2.Tab to “Card Select” and press the space bar to toggle between “Active” and “Standby”. Press Enter.

3.To view the next 11 entries, tab to the [Next] button and press Enter.

4.To view the previous 11 entries, tab to the [Previous] button and press Enter.

5.To clear the entire log, tab to the [Clear] button and press Enter. A prompt appears asking you to confirm the clear. Type y and press Enter. The Alarm Log clears.

Setting Alarm Thresholds

In the Alarm Thresholds screen, you can specify some of the conditions that trigger and clear the system alarms. Each threshold is counted in one second increments, and for most alarms, you can set one threshold to trig- ger the alarm and another to clear it (ES and SES alarms do not need Alarm Off thresholds because they clear automatically when the time span on which they are based passes).

4-42

Telect, Inc. 122188-10 A0

Page 88
Image 88
Telect MIX 56 user manual Setting Alarm Thresholds, 4-42, Step Action