2.In the System Name field, type a name for the system (up to 16 characters) and press Enter. This name appears at the top of each screen in the Craft interface.
3.Tab to the System Location field, type the location of the system (up to 16 characters), and then press Enter.
4.Tab to the Contact Person field, type the name of the person users should contact about the system (up to 16 characters), and then press Enter.
5.Tab to the Date field and type the current date in the format dd/mon/yy where “dd” is the day of the month, “mon” is the first 3 characters of the month name, and “yy” is the year
NOTE
The forward slash (/) must be used in entering the date. The colon (:) must be used in entering the time.
6.Tab to the Time field and type the current time in military time for- mat. Press Enter after typing in the time (hh:mm:ss).
7.Tab to the AIS Terminates LB field, specify whether receiving an AIS signal will terminate any loopbacks that are set by pressing the space bar to toggle between Yes and No, and then press Enter.
8.Tab to the Low Speed Type field, specify the
9.Tab to the LS Remote LB Dir field, specify which direction to re- ceive and transmit
10.Tab to the Active Card field, specify which M13 card by pressing the spacebar to toggle between 1 and 2, then press Enter.
If you are switching active cards, a prompt appears asking you to confirm the change.
a.Type y and press Enter. The current session is terminated.
b.Press Enter to start a new session. If you are using Telnet, you must first reestablish the connection to the system.
Telect, Inc. |