3 8 T RO U B L E S H O OT I N G
Troubleshooting:
F7: RTD FAULT (RTD Failure)
Replace the RTD (page
YES
Open the right end bell.
Is the RTD damaged or defective (page 23)?
NO
Is the RTD connected properly to the I/O control board
(page 45)?
NO
Replace RTD |
|
|
|
| YES | ||
(page |
|
| |
|
|
| |
|
| ||
|
|
|
|
Is the RTD open? Using an ohmmeter, measure at the control board (pages 45- 47). RTD should measure approxi- mately
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Correct wiring | ||
|
|
|
|
| YES |
|
|
| ||||
|
|
|
|
|
|
|
| (page 45). | ||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Replace the I/O |
| ||||
|
|
|
|
|
|
| control board |
| ||||
|
| NO |
|
|
|
| ||||||
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| (page |
| ||||
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Troubleshooting:
F8: HIGH LIMIT TRIPPED (High Limit Trip)
YES
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Are all the contacts |
Is the high limit thermostat |
|
|
| ||||
|
|
|
| closed on the high | |||
| NO |
|
| ||||
tripped (page 21)? |
|
|
| ||||
|
|
|
| limit thermostat? | |||
|
|
|
| ||||
|
|
|
|
|
|
| |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
Reset and determine why it tripped - over temp, blower failure, etc.
Check if the high limit probe or RTD is damaged or defec- tive, replace if needed (page
Ensure that the minimum gas pressure is correctly set, reset if needed (page 3).
YES
Replace the I/O control board (page
Is the wiring correct (page 45)?
NO
Correct wiring (page 45).
YES NO
Replace the high limit thermostat (page