THE CONTROL SYSTEM

23

I S S U E

R E S O L U T I O N

 

 

F2: Cook Temperature

1. Verify the high-limit thermostat is not tripped.

Low

†

If high-limit is tripped, reset and allow the oven to warm up.

 

†

If high-limit is not tripped, follow the instructions below.

High-limit thermostat is not tripped.

Place a small water load in a microwave/heat-resistant container (approx. 275 ml) in the oven and place the oven in TEST MODE. Press the MGTRON key to actuate the microwave. While holding down the MGTRON key, watch the CC and IR temperatures. If either temperature bounces substantially, there may be a noise (EMI) problem.

To correct this problem, examine the wire routing for each thermocouple wire. If the wires are routed near any high voltage components such as the magnetron or high voltage transformers, re- route the wires. If this does not correct the problem, verify that both magnetrons are securely mounted. Call Technical Support for further details at 800.90TURBO or +1 214-379-6000.