Table 3. Local Mode Programming Instructions - Continued

Note: *Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

 

 

 

 

4.

Program the next function code or exit programming mode by entering 99

 

 

on Series 500 Keyboard numeric keypad or by swiping the

 

 

Programmer's card. If using the optional 3-pos ition keyswitch, move

 

 

switch out of the AUX position.

 

 

 

 

19

1.

While in programming mode, at the Series 500 Keyboard numeric keypad, enter

MSR Send

 

applicable Function Code 19.

 

 

 

 

LED (2) turns on.

 

 

2.

At the Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) per

 

 

list below to select MSR data from one or both good tracks.

 

 

 

0 = send any good track*

 

 

 

 

1 = send only if all enabled tracks good

 

3.

Program the next function code or exit programming mode by entering 99 on Series

 

 

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the

 

 

optional 3-position keyswitch, move switch out of the AUX position.

 

 

 

20 or 30

1.

While in programming mode, at the Series 500 keyboard numeric keypad, enter

Comm (RS232)

 

Function Code 20 (Port 0) or 30 (Port 1).

 

Main Port 0 (20)

 

 

 

 

AUX Port 1 (30)

 

 

LED (2) turns on.

 

Baud Rate

 

 

 

 

2.At Series 500 Keyboard numeric keypad, enter the applicable number (1 through 9) to select baud rate per list below.

1 = 300

6

= 9600*

2

= 600

7 = 19200

3

= 1200

8

= 38400

4

= 2400

9

= 57600

5

= 4800

 

 

LED (2) turns off.

3.Program the next function code or exit programming mode by entering 99 on Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the optional 3-position keyswitch, move switch out of the AUX position.

23

Page 31
Image 31
Ultimate Technology 500 POS manual 20 or