Table 3. Local Mode Programming Instructions - Continued
Note: *Default Settings
Function Code(s) | Operation | Normal Indication | Remarks | |
|
|
| ||
| 4. | Program the next function code or exit programming mode by entering 99 | ||
|
| on Series 500 Keyboard numeric keypad or by swiping the | ||
|
| Programmer's card. If using the optional | ||
|
| switch out of the AUX position. |
| |
|
|
| ||
19 | 1. | While in programming mode, at the Series 500 Keyboard numeric keypad, enter | ||
MSR Send |
| applicable Function Code 19. |
| |
|
|
| LED (2) turns on. |
|
| 2. | At the Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) per | ||
|
| list below to select MSR data from one or both good tracks. | ||
|
|
| 0 = send any good track* |
|
|
|
| 1 = send only if all enabled tracks good | |
| 3. | Program the next function code or exit programming mode by entering 99 on Series | ||
|
| 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the | ||
|
| optional | ||
|
|
| ||
20 or 30 | 1. | While in programming mode, at the Series 500 keyboard numeric keypad, enter | ||
Comm (RS232) |
| Function Code 20 (Port 0) or 30 (Port 1). |
| |
Main Port 0 (20) |
|
|
|
|
AUX Port 1 (30) |
|
| LED (2) turns on. |
|
Baud Rate |
|
|
|
|
2.At Series 500 Keyboard numeric keypad, enter the applicable number (1 through 9) to select baud rate per list below.
1 = 300 | 6 | = 9600* | |
2 | = 600 | 7 = 19200 | |
3 | = 1200 | 8 | = 38400 |
4 | = 2400 | 9 | = 57600 |
5 | = 4800 |
|
|
LED (2) turns off.
3.Program the next function code or exit programming mode by entering 99 on Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the optional
23