Table 5. Remote Programming Mode Commands - Continued
OP | MNEMONIC/DESCRIPTION | COMMAND/ACKNOWLEDGEMENT | |
CODE |
|
|
|
(HEX) |
|
|
|
|
|
| |
A3 | COMMP | COMMAND: A3Pbbbbbwsph<CR> | |
| Communications setup for | A3 | = Op Code |
| selecting ports, baud rate, word | P | = destination port for load |
| length, stop bits, parity, and method | bbbbb | = baud rate |
| of handshaking. | W | = word length 7 or 8 bits |
|
| s | = number of stop bits 1 or 2 |
|
| p | = parity odd, even, or none |
|
| h | = handshaking |
|
| <CR> | = terminate command (0D hex) |
|
| Port: | 0 = main; 1 = AUX |
|
|
| |
|
| Baud rate: | |
|
|
| 00300, 00600, 01200, |
|
|
| 02400, 04800, 09600, |
|
|
| 19200, 38400, 57600 |
|
| Word length: | |
|
|
| 7 or 8 |
|
| Stop bits: | |
|
| Parity: | 1 or 2 |
|
| O = odd, E = even, N = none | |
|
|
| |
|
| Handshaking: | |
|
|
| H = CTS/RTS, S = XON/XOFF, |
|
|
| B = both, N = none |
|
| ACKNOWLEDGEMENT: NONE | |
|
|
| |
A4 | NOTES | COMMAND: | |
| Used to enter up to 40 characters | A4 | = Op Code |
| of notes into RAM. Useful for | xx | = Note (max of 40 Characters) |
| recording keyboard version and | <CR> | = terminate command (0D hex) |
| date, etc. |
|
|
|
| ACKNOWLEDGEMENT: NONE | |
|
|
|
|