Table 5. Remote Programming Mode Commands - Continued

OP

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

CODE

 

 

 

 

(HEX)

 

 

 

 

 

 

 

B2

SENDP

COMMAND: B2p...........<CR>

 

Sends data to selected port: main

B2

= Op Code

 

serial port, auxiliary serial port, or

p

= data destination port

 

auxiliary keyboard port.

<CR>

= terminate command (0D hex)

 

 

p:

0

= serial port 0 (main)

 

 

 

 

 

 

1

= serial port 1 (auxiliary)

 

 

 

2

= keyboard port 0 (main)

 

 

 

3

= keyboard port 1 (auxiliary)

 

 

 

4 = cash drawer 1 fire

 

 

 

5

= cash drawer 2 fire

 

 

Where data can be ASCII or CxDx (high and

 

 

low nibble hex value) type.

 

 

ACKNOWLEDGEMENT: NONE

 

 

 

B3

RDERROR

COMMAND: B3<CR>

 

Sends all error information to main

B3

= Op Code

 

port for output.

<CR>

= terminate command (0D hex)

 

 

Sends all error log information contained in

 

 

the non-volatile memory (NVRAM) out the

 

 

main port.

 

 

ACKNOWLEDGEMENT: NONE

 

 

 

 

 

46

Page 54
Image 54
Ultimate Technology 500 POS manual MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT Code HEX Sendp, Command B2p...........CR