Table 5. Remote Programming Mode Commands - Continued

OP

MNEMONIC/DESCRIPTION

COMMAND/ACKNOWLEDGEMENT

CODE

 

 

 

 

 

 

(HEX)

 

 

 

 

 

 

 

 

 

 

 

B1

BEEPON

COMMAND: B1pd<CR>

 

 

 

Controls pitch and duration of beep.

B1

= Op Code

 

 

 

If valued for pitch (p) and duration

p

= pitch in Hz

 

 

 

(d) omitted when command

d

= duration in milliseconds

 

activated.

<CR>

= terminate command (0D hex)

 

 

pitch (Hz) in ASCII

 

 

 

 

 

0

= 500

5

= 880

 

 

 

1

= 2000

6

= 1320

 

 

 

2

= 220

7

= 1760

 

 

 

3

= 440

8

= 2640

 

 

 

4

= 660

9

= 3520

 

 

duration (mS) in ASCII

 

 

 

 

 

0

= 1000

5

= 500

 

 

 

1

= 100

6

= 600

 

 

 

2

= 200

7

= 700

 

 

 

3

= 300

8

= 800

 

 

 

4

= 400

9

= 900

 

 

ACKNOWLEDGEMENT:

NONE

 

 

 

 

 

 

 

45

Page 53
Image 53
Ultimate Technology 500 POS manual Command B1pdCR