Table 3. Local Mode Programming Instructions - Continued

Note: *Default Settings

Function Code(s)

Operation

Normal Indication

Remarks

70

1.

While in programming mode, at Series 500 Keyboard numeric keypad, enter Function

Indicator LED

 

Code 70.

 

 

Mode (70)

 

 

 

 

 

 

 

LED (2) turns on.

 

 

2.

At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) to

 

 

select LED mode of operation.

 

 

 

 

LED Mode

 

 

 

 

0 = Command mode of operation*

 

 

 

1 = PC mode of operation

 

 

 

 

LED (2) turns off.

 

 

3.

Program the next function code or exit programming mode by entering 99 on Series

 

 

500 Keyboard numeric keypad or by swiping the Programmer's card. If using the

 

 

optional 3-position keyswitch, move switch out of the AUX position.

 

 

 

71

1.

While in programming mode, at Series 500 Keyboard numeric keypad, enter Function

Enable/Disable

 

Code 71.

 

 

Keyboard Key

 

 

 

 

Clicks (71)

 

 

LED (2) turns on.

 

2.At Series 500 Keyboard numeric keypad, enter the applicable number (0 or 1) to select key click mode of operation.

Key Click Mode

0 = off

1 = on*

LED (2) turns off.

3.Program the next function code or exit programming mode by entering 99 on Series 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the optional 3-position keyswitch, move switch out of the AUX position.

29

Page 37
Image 37
Ultimate Technology 500 POS manual Indicator LED Code Mode