Table 3. Local Mode Programming Instructions - Continued
Note: *Default Settings
Function Code(s) | Operation | Normal Indication | Remarks | |
|
|
| ||
23 or 33 | 1. | While in programming mode, at Series 500 Keyboard numeric keypad, enter Function | ||
Main Port 0 (23) |
| Code 23 (Port 0) or 33 (Port 1). |
| |
AUX Port 1 (33) |
|
|
|
|
Handshaking |
|
| LED (2) turns on. |
|
| 2. | At Series 500 Keyboard numeric keypad, enter the applicable number (0, 1, 2 or 3) to | ||
|
| select handshaking per list below. |
| |
|
|
| 0 = None |
|
|
|
| 1 = CTS/RTS |
|
|
|
| 2 = XON/XOFF |
|
|
|
| 3 = Both* |
|
|
|
| LED (2) turns off. |
|
| 3. | Program the next function code or exit programming mode by entering 99 on Series | ||
|
| 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the | ||
|
| optional | ||
|
|
| ||
24 or 34 | 1. | While in programming mode, at Series 500 Keyboard numeric keypad, enter Function | ||
Main Port 0 (24) |
| Code 24 (Port 0) or 34 (Port 1). |
| |
AUX Port 1 (34) |
|
|
|
|
Word Length |
|
| LED (2) turns on. |
|
| 2. | At Series 500 Keyboard numeric keypad, enter the applicable number (7 or 8) to | ||
|
| select word length per list below. |
| |
|
|
| 7 = 7 data bits |
|
|
|
| 8 = 8 data bits |
|
|
|
| LED (2) turns off. |
|
| 3. | Program the next function code or exit programming mode by entering 99 on Series | ||
|
| 500 Keyboard numeric keypad or by swiping the Programmer's card. If using the | ||
|
| optional | ||
|
|
|
|
|
25