Mounting

Average Temperature/Water Bottom Sensor and Converter

 

 

5.2Mounting on a fixed roof tank

There are three methods for mounting the 4532 ATC on a fixed roof tank:

Top anchor method

Thermo well method

Anchor weight method

If the tank bottom has a heating coil, the clearance from the flexible tube bottom hook to the tank bottom may increase depending on the heating coil type.

5.2.1Top anchor method

The flexible tube is stabilized by a wire hook and a top anchor.

Top anchor

Electrical compartment

Cable entry as specified

Flange

Socket (1")

Tensioning wire

Flexible tube

 

From tank bottom to element position #1 approx.500 mm(20")

Tank bottom

Wire hook

Ø26 mm(1.02")

Clearance below bottom hook

400 mm (15.57")

Figure 5-2: Top anchor application

1.Insert a gasket and lower the flexible tube from the nozzle on the tank top.

Caution! The flexible tube must be lowered carefully without bending too much and scratching at the inner edge of the nozzle hole.

2.Rotate the 4532 ATC so that you can set up the cabling in the most convenient way.

3.Straighten the tensioning wire, fix the wire end to the top anchor temporarily and lower the wire.