4532

Mounting

 

 

5.3.3Guide ring and anchor weight method

The flexible tube is stabilized by a guide ring and anchor weight.

Electrical compartment

Cable entry as specified

 

Flange

 

Flexible tube

 

Guide ring

Element position #1

Ø26mm (1.02")

 

(Bottom element)

 

 

Clearance below

 

bottom hook

500mm (20")

 

 

400mm (15.75)

Tank bottom

 

Figure 5-10:Guide ring and anchor weight application

Caution! Make sure to put the anchor weight on the tank bottom. When installing with the sus- pended anchor weight, please use the anchor weight at a maximum of 16kg. More weight may cause internal breaking in the flexible tube.

Caution! The flexible tube must be lowered carefully without bending too much and scratching at the inner edge of the nozzle hole.

1.Set the guide ring to the floating roof.

2.Insert a gasket and lower the flexible tube from the nozzle on the tank top.

3.Rotate the 4532 ATC so that you can set up the cabling in the most convenient way.

4.Tighten the tensioning wire between the lower end of the flexible tube and the anchor weight. Wind the tensioning wire twice around each of the hitches and wrap a wire around it (see Figure 5-7 on page 16).

5.Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.