4532 | Technical data |
|
|
12 Technical data
Technical data at a glance:
Application
Application
The 4532 ATC performs precise liquid and gas phase average temperature measurement in bulk storage tank applications.
•Standard 2" flange installation
•Overall 18.5m temperature measurement range
Function and system design
Measuring principle
Temperature measurement
•Up to 6 elements spaced evenly over the length of the flexible tube.
•Pt100, Class A elements
Input
Measured variable | Temperature measurement |
| Temperature conversion range: |
|
|
Measuring range | |
|
|
Output |
|
|
|
Output signal | • HART protocol (multi drop HART loop connection) |
|
|
Signal on alarm | Error information can be accessed via the following interfaces and |
| transmitted digital protocol (refer to the operation manuals on |
| following instruments) |
| • Tank Side monitor 4590 TSM |
| • 6000 Series Servo Tank Gauge |
|
|
Auxiliary energy |
|
|
|
Load HART | Minimum load for HART communication: 250 W |
|
|
Cable entry | see technical document |
|
|
Supply voltage | 16 ~ 30VDC (on multi drop HART loop) |
|
|
Current consumption | Less than 6mA |
|
|
Performance characteristics | |
|
|
Reference operating | • temperature = +25 °C (77 °F) ±5 °C (9 °F) |
conditions | • pressure = 1013 mbar abs. (14.7 psia) ±20 mbar (0.3 psi) |
| • relative humidity (air) = 65 % ± 20% |
|
|
Maximum measured | Typical statements for reference conditions, include linearity, |
error | repeatability, and hysteresis: |
| • Linearity: |
| • Temperature: ±0.15°C (0.27°F) + number of element deviation |
| (based on IEC class A standard) |
|
|
Varec, Inc. | 51 |