Varec 4532 manual Tensioning wire mounting

Models: 4532

1 70
Download 70 pages 2.13 Kb
Page 25
Image 25

4532

Mounting

 

 

4.Draw the tensioning wire through the wire hook on the tank bottom.

5.Wrap the tensioning wire twice around the hole on the bottom hook, tighten it and wrap the provided wire around it (see Figure 5-3).

Tensioning wire

Flexible tube

 

Bottom hook

 

Wire hook

Provided wire

Figure 5-3: Tensioning wire mounting

6.Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.

Note! Please keep the compression of the spring at 35 to 37 mm (1.38 to 1.47).

If you compress the spring over 35 to 37 mm, it may cause damage to the sensor.

7.Draw the end of the tensioning wire as much as possible by hand and foot (see Figure 5-4)

8.Bend the wire and fix it using the nut.

9.Cut the excess wire.

10.Screw the nut to compress down the spring of the top anchor 35 to 37 mm.

11.Cover the top anchor.

35~37mm

Figure 5-4: Top anchor mounting