4532

Operation and Description of Instrument Function

 

 

VH80: Present Error

Item type: read only

Display of current error message. One of the following codes will be indicated:

Error code

0: No error presence

1: Common line open

2: undetermined

3: #1 element open

4: #1 element short

5: #2 element open

6: #2 element short

7: #3 element open

8: #3 element short

9: #4 element open

10: #4 element short

11: #5 element open

12: #5 element short

13: #6 element open

14: #6 element short

23: #0 element over range

24: Memory defect (ROM)

29: Element exposed (liquid level below #1 element position)

30: undetermined

31: undetermined

41: Memory defect (RAM)

42: Memory defect (EEROM)

VH81 Temperature Unit

Item type: select

Default: °C

Selection: C, F, K

Selection of temperature display unit. Based on universal HART setting, °C(HART code: 32), °F(HART code: 33) and °K(HART code: 35) are available.

Note! Selection of temperature display unit only applies to reply data from 4532 ATC. Data transmission from host gauge (4590 TSM or 6000 Series Servo Tank Gauge) to 4532 ATC must be performed by °C unit only (terminology of HART command 133)