Operation and Description of Instrument Function

Average Temperature/Water Bottom Sensor and Converter

 

 

VH48 Gas Offset

Item type: read and write

Default: 300mm

Range: 0mm ~ 99999mm

A function to exclude specific element(s) from the gas (vapor) phase average temperature calculation when the uncovered element(s) is (are) within the entered value from the liquid level.

To 4532 ATC Electric housing

Temperature

Element

VH48 GAS Offset 300mm (default)

Gas phase

Temp. element within this range will be excluded from Gas average calculation

Liquid Level

Liquid phase

To Tank floor

VH49 Liquid Offset

Item type: read and write

Default: 300mm

Range: 0mm ~ 99999mm

A function to exclude element (s) from the liquid phase average temperature calculation when the uncovered element(s) is (are) within the entered value from the liquid level.

To 4532 ATC Electric housing

Gas phase

Temperature

Element

Liquid Level

VH49 Liquid Offset: 300mm (default)

Temp. element within this range will be excluded fr om liquid average calculation

Liquid phase

To Tank floor