Varec 4532 VH92 Error Dis. Sel, VH94 Polling Address, VH95 Manufacture ID, VH96 Software Version

Models: 4532

1 70
Download 70 pages 2.13 Kb
Page 54
Image 54

Operation and Description of Instrument Function

Average Temperature/Water Bottom Sensor and Converter

 

 

VH92 Error Dis. Sel.

Item type: select

Default: 0_OFF

Selection: 0_OFF, 1_ON

Type of VH88 "Short Error Value" and VH89 "Open Error Value" display selection.

0_OFF: These 2 error messages will not be transmitted to the connected host gauge. This function automatically excludes defect element in average temperature calculation.

1_ON: Error message will be transmitted to the host gauge. As a result, VH88 and 89"s numeric error code will be displayed on host gauge default screen and may transmit to upper receiver as well.

VH94 Polling Address

Item type: read and write

Default: 2

Range: 1 ~ 15

Polling address for HART communication

VH95 Manufacture ID

Item type: read only

Default: 17

The manufacturer ID for Endress+Hauser instrumentation.

VH96 Software Version:

Item type: read only

A display of installed software version.

VH97 Hardware Version

Item type: read only

A display of installed hardware version.

VH98 Below Bottom

Item type: select

Default: 0_OFF

Selection: 0_OFF, 1_ON

A type of error display when liquid level drops below #1 element (Bottom Point). Error code "29" is displayed on VH80 and VH91 when 0_ON is selected.

VH99 Device Type Code

Item type: read only

Device type will be displayed.

190: Temperature measurement function only.

44

Installation and Operations Manual

Page 54
Image 54
Varec 4532 VH92 Error Dis. Sel, VH94 Polling Address, VH95 Manufacture ID, VH96 Software Version, VH97 Hardware Version