4532 | Mounting |
|
|
5.2.3Anchor weight method
The flexible tube is stabilized by an anchor weight:
Electrical compartment
Cable entry as specified
Flange
222 mm(8.74") | |
| Flexible tube |
Ø120 mm(4.72") | |
1000mm(39.37") | |
41mm(1.61") | |
From tank bottom to | Ø26 mm(1.02") |
| |
element position #1 | Clearance below |
approx.500 mm (20") | |
| bottom hook |
| 400 mm (15.57") |
| Tank bottom |
Nozzle height
Tank height
Figure 5-6: Anchor weight application
Note! Make sure to put the anchor weight on the tank bottom. When installing with the sus- pended anchor weight, please use the anchor weight at a maximum of 16 kg. More weight may cause internal breaking in the flexible tube.
Caution! The flexible tube must be lowered carefully without bending too much and scratching at the inner edge of the nozzle hole.
1.Insert a gasket and lower the flexible tube from the nozzle on the tank top.
2.Rotate the 4532 ATC so that you can set up the cabling in the most convenient way.
3.Tighten the tensioning wire between the lower end of the flexible tube and the anchor weight.
4.Wrap the tensioning wire twice around a hole on the bottom hook, tighten it and wrap a provided wire around it (see Figure
5.Fix the mounting flange of the 4532 ATC to the nozzle on the tank top using bolts.
Varec, Inc. | 17 |