8315 L&J Tankway Software Description

TankGate Interface

 

 

4.16 System Information (SYS)

The System Information Point lists the hardware and software specifications of the system. Other information includes the hardware version and any connected devices.

4.16.1Parameters

The database parameters used by the SYS point are listed and described below:

Configuration

Function

Parameters

 

 

 

RTUTag

RTUTag can contain 15 bytes of data and can include any printable

 

ASCII character.

 

 

DBFile

The database file name. DBFile is the name of the RCF database

 

configuration file

 

 

DBVer

The database version

 

 

PntEnable

Disable/Enable execution of points. Default is Enable

 

 

Dynamic Parame-

Function

ters

 

 

 

UnitAddr

The TankGate Unit Address (SW1)

 

 

DBPnts

The number of database points defined

 

 

DBSize

The size of the database in bytes

 

 

DBChangeTime

The time of last database modification

 

 

SysVer

The Firmware version

 

 

SysCheckSum

The System Checksum

 

 

HardVer

The PCB hardware version

 

 

PSDVer

The programmable logic version

 

 

PntCheckSum

CRC-16 Checksum for point's static Configuration Parameters

 

 

52

Installation and Operations Manual

Page 62
Image 62
Varec 8315 Series manual System Information SYS