8315 L&J Tankway Software Description

 

 

4.17 L&J MCG1000 Tank Gauge (LJ1000)

The LJ1000 point provides an interface to L & J MCG1000 Tank Gauge transmitters. This point provides both level and temperature data. Point and gauge status information is also available in this point block. This point executes on the Model 8315 Tank Gauge Interface module.

4.17.1Parameters

The database parameters used by the LJ1000 point are listed and described below:

Configuration

Function

Parameters

 

 

 

Tag

A Tag can contain 15 bytes of data and can include any printable ASCII

 

character. Tags can be used to identify the name of the tank being

 

monitored The default tag is set to “LJ1000.00”.

 

 

Description

A description can contain 30 bytes of data and can include any printable

 

ASCII character.

 

 

ID

Physical Address (0-127). The default is 0

 

 

DevType

Tank Gauge Type.

 

DevTypeTank Gauge Type.

 

DevType = 1 Uses a gray code table for CCW Varec gauges

 

DevType = 2 Uses a gray code table for CCW S&J gauges

 

DevType = 3 reports data in feet and hundredths of a foot

 

DevType = 4 reports data in 32nds of inches

 

 

Module

Physical address (1-4) of the Model 3215 used to interface to the tank

 

gauge transmitter. A value of 255 is undefined.

 

 

Filter

Gauge data filter constant. The Filter is used when scanning data from

 

an L&J gauge. A buffer is maintained for the last 8 readings. The Filter

 

determines how many of the reading in the buffer are used when

 

calculating the Level and Temp parameters. If all of the level readings

 

are within a deadband determined by the LJSCAN LevelDeadband

 

parameter, then the Level reading is updated with the latest data. If a

 

large change is detected (data changed more than the LevelDeadband),

 

then the Level is not updated until the change between readings is less

 

than the LevelDeadband. The default is 3.

 

 

TempDeadband

Change of State temperature deadband value. This parameter is used

 

when the Report is High or Low to determine if a change of state has

 

occurred. This parameter does not affect the Temp parameter value,

 

only if it is automatically sent to the Host system.

 

 

LevelDeadband

Change of State level deadband value. This parameter is used when the

 

Report is High or Low to determine if a change of state has occurred.

 

This parameter does not affect the Level parameter value, only if it is

 

automatically sent to the Host system.

 

 

Report

Causes automatic notification to the Host (in response to a Change of

 

State Request) when the Value Changes State. Parameter value can be

 

High, Low or No. Report=No disables notification. Points with Report =

 

High will be sent before points with Report = Low. The default is High.

 

 

53

Page 63
Image 63
Varec 8315 Series manual 17 L&J MCG1000 Tank Gauge LJ1000