Appendix

TankGate Interface

 

 

1.2.1Modbus Map

Address

Type

Number

Parameter

Data Type

 

 

 

 

 

5000

LJ2000

0

Command

CODED

 

 

 

 

 

5001

LJ2000

0

Level

REAL

 

 

 

 

 

5003

LJ2000

0

Temp

REAL

 

 

 

 

 

5005

LJ2000

0

Value

REAL

 

 

 

 

 

5007

LJ2000

0

Status

HEX

 

 

 

 

 

5008

LJ2000

0

PntStatus

IHEX

 

 

 

 

 

5009

LJ2000

0

Elapse

TIME

 

 

 

 

 

There are a total of 50 GPE points. There are a total of 11 registers available per gauge. The addresses are sequential. The addresses range from 5000 to 5550

4000

SCALER

0

Value

 

REAL

 

 

 

 

 

 

4002

SCALER

0

Value1

 

INTEGER

 

 

 

 

 

 

4003

SCALER

0

PntStatus

 

UBYTE

 

 

 

 

 

 

4004

SCALER

0

Elapse

 

TIME

 

 

 

 

 

 

4006

SCALER

1

Value

 

REAL

 

 

 

 

 

 

4008

SCALER

1

Value1

 

INTEGER

 

 

 

 

 

 

4009

SCALER

1

PntStatus

 

UBYTE

 

 

 

 

 

 

4010

SCALER

1

Elapse

 

TIME

 

 

 

 

 

 

There are a total of 16 SCLAER points. There are a total of 11 registers available per SCALER point

The addresses are sequential. The addresses

range from 4000 to 4095

 

 

 

 

 

 

 

 

 

 

1000

IREG

0

Value1

 

UINTEGER

 

 

 

 

 

 

1001

IREG

0

Value2

 

UINTEGER

 

 

 

 

 

 

1002

IREG

0

Value3

 

UINTEGER

 

 

 

 

 

 

1003

IREG

0

Value4

 

UINTEGER

 

 

 

 

 

 

1004

IREG

0

Value5

 

UINTEGER

 

 

 

 

 

 

1005

IREG

0

Value6

 

UINTEGER

 

 

 

 

 

 

1006

IREG

0

Value7

 

UINTEGER

 

 

 

 

 

 

1007

IREG

0

Value8

 

UINTEGER

 

 

 

 

 

 

1008

IREG

0

Value9

 

UINTEGER

 

 

 

 

 

 

1009

IREG

0

Value10

 

UINTEGER

 

 

 

 

 

 

1010

IREG

0

Value11

 

UINTEGER

 

 

 

 

 

 

ii

Installation and Operations Manual

Page 114
Image 114
Varec 8315 Series manual Modbus Map, Address Type Number Parameter Data Type