The manual gas valve, located behind the small door in the lower front panel, should remain off until all electrical and gas connections are made and the ovens are ready to be used.
LEVELING
Ensure that the oven racks are level in the final installed position. If the oven is installed on legs, turn the adjustable feet in or out to level the oven
ELECTRICAL CONNECTIONS
WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING: APPLIANCES EQUIPPED WITH FLEXIBLE ELECTRICAL POWER SUPPLY CORD ARE PROVIDED WITH A
The SG series ovens are equipped with a 120 volt / 60 Hz. / 1 phase cord and plug.
Refer to the Installation Codes and Standards section of this manual.
A schematic decal is located on the inside of the right side panel.
GAS AND ELECTRICAL DATA
|
| GAS DATA |
|
|
|
| ELECTRICAL | |||
|
|
|
|
|
| |||||
|
|
|
|
|
| DATA | ||||
|
|
|
|
|
|
|
|
|
| |
MODEL |
|
|
|
|
|
|
|
|
|
|
INPUT BUT/HR | MANIFOLD PRESSURE | AMP LINE | ||||||||
|
|
|
|
|
|
|
|
|
|
|
| Natural | Propane | Natural |
|
| Propane | 120 Volts | |||
|
|
|
|
|
|
|
|
|
|
|
SG4D/C |
|
|
|
|
|
|
|
|
|
|
60,000 | 60,000 | 3.5" (03.875" |
| kPa) | 10" |
| (2.1490" | kPa) | 9 Amps | |
SG6D/C |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
SG44D/C |
|
|
|
|
|
|
|
|
|
|
120,000 | 120,000 | 3.5" (03.875" |
| kPa) | 10" |
| (2.1490" | kPa) | 18 Amps | |
SG66D/C |
|
| ||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
— 9 —