318 VT1422A Command Reference Chapter 7
OUTPut
Related Commands: OUTPut:SHUNt, SENSe:FUNCtion:STRain,
[SENSe:]STRain
*RST Condition: OUTP:SHUNT:SOURCE INT on all VT1529A/B channels
Send with VXIplug&play Function: hpe1422_cmd(...)
Usage OUTP:SHUNT:SOUR EXT,(@10000,10800) select user supplied shunt resistor on
VT1529As connected to channels 0, 1, 8,
and 9

OUTPut:SHUNt:SOURce?

OUTPut:SHUNt:SOURce? (@<channel>) returns the source of the shunt
resistance on the specified VT1529A/B Strain channel.
Parameters

Comments The <channel> parameter must specify a single channel only and since there is

a single shunt resistor for all channels on a VT1529A/B, it can be any channel
on the VT1529A/B.
If <channel> specifies a non VT1529A/B channel, a 3007 "Invalid signal
conditioning plug-on" error is generated.
Returned Value: Returns "INT" or "EXT." The data type is string.
Related Commands: OUTP:SHUNT:SOUR
Send with VXIplug&play Function: hpe1422_cmdString_Q(...)
Usage OUTPUT:SHUNT:SOURCE? (@11600) Check source of shunt resistance on
VT1529A/B connected to channel 16
Parameter
Name Parameter
Type Range of
Values Default
Units
channel channel list (string) 10000 - 15731 none