64 Programming the VT1422A & VT1529A/B for Remote Strain Measurement Chapter 3
Spring and ScrewTerminal Modules

For mixed on-board SCP channels and RSCU operation, spring or screw

type terminal modules can be used. For standard SCP channel connections,

see Chapter 2 “Field Wiring” on page 35. For remote channels, connect the

individual wires from each VT1529A/B’s data interface cable to the

appropriate terminals for remote channel operation. The VT1539A SCP is

supplied with signal locator labels for each SCP position on a Spring

Terminal Module. No label is provided for the Screw terminal module.

Instead, Table 3-3 provides the relationship between each VT1539A signal

name and associated terminal name as printed on the Terminal Module.

Note: In the table below, color combinations may vary.

Table 3-3. VT1539A Signal Names
SCP Signal Names - to - Terminal Names
SCP Position Plug
Pin#
VT1539A Signal Name
(with EIA/TIA-568A
wire color-code)
Terminal Name on
Terminal Module
(SCP’s low channel)
Terminal Name on
Terminal Module
(SCP’s High Channel)
SCP Position 0
Addresses
10000 to 10131
1 Analog+ (wht-green) HI 00 HI 01
2 Analog- (green) LO 00 LO 01
3Cal+ (wht-orange) HI 02 HI 03
4 RS-485+ (blue) HI 04 HI 05
5 RS-485- (wht-blue) LO 04 LO 05
6Cal- (orange) LO 02 LO 03
7 Trigger+ (wht-brown) HI 06 HI 07
8 Trigger- (brown) LO 06 LO07
SCP Position 1
Addresses
10800 to 10931
1 Analog+ (wht-green) HI 08 HI 09
2 Analog- (green) LO 08 LO 09
3Cal+ (wht-orange) HI 10 HI 11
4 RS-485+ (blue) HI 12 HI 13
5 RS-485- (wht-blue) LO 12 LO 13
6Cal- (orange) LO 10 LO 11
7 Trigger+ (wht-brown) HI 14 HI 15
8 Trigger- (brown) LO 14 LO16
SCP Position 2
Addresses
11600 to 11731
1 Analog+ (wht-green) HI 16 HI 17
2 Analog- (green) LO 16 LO 17
3Cal+ (wht-orange) HI 18 HI 19
4 RS-485+ (blue) HI 20 HI 21
5 RS-485- (wht-blue) LO 20 LO 21
6Cal- (orange) LO 18 LO 19
7 Trigger+ (wht-brown) HI 22 HI 23
8 Trigger- (brown) LO 22 LO23