Wayne-Dalton 3663-372 To Reduce The Risk Of Severe Injury Or Death, Important Safety Instructions

Models: 3663-372

1 52
Download 52 pages 50.34 Kb
Page 40
Image 40
IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

 

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH:

1.READ AND FOLLOW ALL INSTRUCTIONS.

2.Never let children operate or play with the door controls. Keep remote controls away from children.

3.Always keep a moving door in sight and keep people and objects away until it is completely closed. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR.

4.NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.

5.Test the Door/Opener monthly. The garage door MUST reverse on contact with a 1-1/2” high object (or a 2 x 4 board laid flat) on the floor. The door MUST also reverse when a 6” high object is placed on the floor in line with safety sensors. If Door/Opener fails these tests, have adjustments/repairs made immediately. Failure to make adjustments/repairs may cause severe or fatal injury.

6.When possible, use the Emergency Disconnect only when the door is in the closed position. Be very cautious using the Emergency Disconnect when the door is open. Weak or broken spring(s) may allow the door to fall rapidly, causing a severe or fatal injury.

7.KEEP THE GARAGE DOOR PROPERLY BALANCED. See the owner’s manual included with the door. An improperly balanced door could cause a severe or fatal injury. Have a qualified service person make repairs to the cables, spring assemblies, and other hardware.

8.SAVE THESE INSTRUCTIONS.

Door activation:

Upon activation by either the Wall Station Up/Down Button or Transmitter, the door will move in the following manner:

1.If closed, the door will open. If open completely, the door will close. If partially open, the door will close.

2.If closing, the door will stop, reverse, and return to the open position. Next activation will close the door.

3.If opening, the door will stop. Next activation will close the door.

4.If an obstruction is encountered or an out-of-balance condition is detected while the door is closing, the door will reverse, return to the open position, and the opener will beep 3 or 4 times. The next activation will close the door.

5.If an obstruction is encountered or an out-of-balance condition is detected while opening the door, the door will stop. The next activation will close the door.

6.When door is in motion any button on the wall station functions the same as the Up/Down button.

4.NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.WARNING

ALWAYS KEEP MOVING DOOR IN SIGHT AND KEEP PEOPLE AND OBJECTS AWAY UNTIL IT IS COMPLETELY CLOSED. TO PREVENT A SEVERE OR FATAL INJURY, AVOID STANDING IN A OPEN DOOR WAY OR WALKING THROUGH THE DOORWAY WHILE THE DOOR IS MOVING.

8.SAVE THESE INSTRUCTIONS.WARNING

NEVER LET CHILDREN OPERATE DOOR OR PLAY WITH THE DOOR CONTROLS. KEEP REMOTE CONTROLS AWAY FROM CHILDREN. FATAL INJURY COULD RESULT SHOULD A CHILD BECOME TRAPPED BETWEEN THE DOOR AND FLOOR.

Manual backgroundWARNING

KEEP THE GARAGE DOOR PROPERLY BALANCED. AN IMPROPERLY BALANCED DOOR COULD CAUSE SEVERE OR FATAL INJURY. HAVE A QUALIFIED SERVICE PERSON MAKE ADJUSTMENTS/REPAIRS TO CABLES, SPRING ASSEMBLIES, AND OTHER HARDWARE.

Emergency Disconnect:

Manual backgroundWARNING

THE EMERGENCY DISCONNECT SHOULD ONLY BE USED WHEN DOOR IS CLOSED. USE EXTREME CAUTION IF OPERATING THE EMERGENCY DISCONNECT ON AN OPEN DOOR. WEAK OR BROKEN SPRING(S) MAY ALLOW THE DOOR TO FALL RAPIDLY, CAUSING SEVERE OR FATAL INJURY.

The opener is equipped with an emergency disconnect that allows the door to be moved manually and independently from the opener.

With the door closed, pull down on the disconnect handle and place the handle under the lower section of the handle bracket. This motion causes the motor on the opener to pivot upwards and the opener to disconnect from the torque tube.

Releasing the disconnect handle from the lower section on the handle bracket and returning the handle to its original position will reconnect the opener to the torque tube.

NOTE: The motor will not pivot down completely when the handle is released. After one motorized up/down door cycle, the motor will once again pivot down, and all cable slack will be taken up. The garage door is not secured from forced entry until the motor is back in the down position.

Disconnect Label: The label is located next to the disconnect handle. The label shows the handle in both the motor operated and manual operated positions. View on the left side of the label shows the handle position when the opener is engaged to the torque tube. The view on the right side of the label shows the handle when the opener is disconnected from the torque tube.

33Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need.

You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Page 40
Image 40
Wayne-Dalton 3663-372 To Reduce The Risk Of Severe Injury Or Death, Important Safety Instructions, Save These Instructions