Adjusting Detent

(Continued)

a. If the motor does not pivot down, or only pivots down partially, the detent pin is set too hard.

Using a flat tip screwdriver, turn the detent pin counterclockwise in 1/8 turn increments.

Operate the door to confirm adjustment.

Repeat procedure until motor pivots

a

to full down position when the door

is completely closed.

b

b. If the motor pivots down prematurely

 

(before the door is completely closed) or

 

if the motor is “slapping” too aggressively

 

against the top of the door, the detent pin

 

is set too soft.

 

Using a flat tip screwdriver, turn the detent pin clockwise in 1/8 turn increments. Operate the door to confirm adjustment.

Repeat procedure until motor pivots to full down position when the door is completely closed.

27

Lock Arm Installation

 

Tools Needed:

Tape Measure

Step Ladder

NOTE: If you have a low headroom double track system, skip this step and continue with Step 28.

Place the emergency disconnect in the manual operated position, Motor will pivot to the up position (see Step 9).

Insert the lock arm into the motor groove and align with the proper hole depending on your track radius. To determine the Wayne-Dalton track radius being used, measure the length of the flagangle and Torquemaster® end bracket and compare to the diagram on the right (all Portland tracks are stamped with radius on the side of the track).

 

 

 

 

 

 

 

Mt. HOPE/

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PORTLAND

 

 

 

 

 

 

 

 

 

 

 

PENSACOLA

 

 

 

Mt. HOPE/

TRACK

 

 

 

 

 

 

 

 

 

15” RADIUS

 

 

 

PENSACOLA

20-

3/4”

 

 

 

 

 

 

 

 

 

21-1/8”

 

 

 

12” RADIUS

 

 

 

 

 

 

 

 

 

 

 

 

19-3/4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lock

Track Type

Track Radius

Door Model

Arm

WD - Mt. Hope &

 

 

Position

Pensacola

 

 

 

PO - Portland

 

 

 

 

 

 

 

WD

15”(380mm)

9700

 

WD

12”(305mm)

8000, 9000

OPERATION

Motor

1

2

3

4

1

12”

9000 Series

PO

PO

10”

8000, 9000

PRE-

Lock

Arm

2

PO

12”

8000 Series

Z-Wave enabled

what’s OPENING your world?

With Z-Wave®technology you can control your lights, thermostat and start your morning coffee, allwiththe single touch of a button.

Motor

Groove

3

WD

15”(308mm)

8000, 9000

PO

14”

9000 Series

 

 

 

 

 

4

PO

14”

8000 Series

Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need. 30 You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com

Page 37
Image 37
Wayne-Dalton 3663-372 installation instructions Operation, Lock Arm Installation