W O L F C O O K T O P V E N T I L A T I O N

E L E C T R I C A L R E Q U I R E M E N T S

Wolf downdraft ventilation systems require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker, and a grounded 3-prong recepta- cle should be located within reach of the 21/2' (.8 m) power cord. The specific location of the outlet is not critical as long as it is within reach of the power cord that is located midway, top and bottom, on the right side of the downdraft.

IMPORTANT NOTE: If Model DD30 is to be installed in a 30" (762) wide cabinet, Model DD36 in a 36" (914) wide cabinet or Model DD45 in a 451/2" (1156) wide cabinet, the electrical outlet cannot be located on the back wall of the cabinet. The outlet may be placed in adjacent cabinetry.

Locate electrical within the shaded area shown in the Installation Specifications illustrations.

IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.

You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.

B L O W E R C O N S I D E R A T I O N S

Except for Models DD30I, DD36I and DD45I, which include a 500 CFM internal blower, Wolf downdrafts are shipped without the blower assembly. In-line and remote blower assemblies are available. The blower will vary in size and is dictated by the cooking surface, the volume of air that needs to be moved and the length of the duct run. A straight, short duct run with a limited number of elbows and transitions will allow the ventilation hood to perform most effi- ciently.

Wolf downdraft ventilation systems are designed for use with 31/4" (83) x 10" (254) ductwork for Models DD30I, DD36I and DD45I and 31/4" (83) x 14" (356) ductwork for Models DD30R, DD36R and DD45R. Each can be transitioned to 8" (203) or 10" (254) round ductwork.

Aremote-mounted blower will minimize the amount of blower noise, but will not eliminate the noise completely.

IMPORTANT NOTE: Install this downdraft system only with a Wolf blower.

Refer to the cooktop ventilation recommenda- tions on pages 115–116.

I N S T A L L A T I O N S P E C I F I C A T I O N S

Location of Electrical Supply

Dimensions in parentheses are in millimeters unless otherwise specified.

24" min (610)

CABINET DEPTH

4" min (102)

 

31/2" (89)

E

 

10" (254)

30" min (762)

FOR MODEL DD30

36" min (914)

FOR MODEL DD36

451/2" min (1156)

FOR MODEL DD45

E

OPTIONAL

ELECTRICAL

LOCATION IN

ADJACENT RIGHT SIDE CABINET

IMPORTANT NOTE: Certain installations may require that the electrical supply be placed in an adjacent cabinet within reach of the power cord. Choose the location shown in the illustra- tion that best suits your installation.