![](/images/new-backgrounds/1084715/84715219x1.webp)
W O L F P R O V E N T I L A T I O N
S P E C I F I C A T I O N S
Pro Hood Liners
Overall Width |
|
PL342212 | 34 3/8" (873) |
PL402212 | 40 3/8" (1026) |
PL462212 | 46 3/8" (1178) |
PL522212 | 52 3/8" (1330) |
PL582212 | 58 3/8" (1483) |
Overall Height | 12" (305) |
Overall Depth | 221/2" (572) |
Bottom of Hood |
|
to Countertop | 30" (762) to 36" (914) |
Duct Size | 10" (254) Round |
Discharge | Vertical |
Internal Blower* | 1200 CFM |
1100 CFM | |
Remote Blowers* | 900, 1200 or 1500 CFM |
O V E R A L L D I M E N S I O N S
Pro Hood Liners
TOP WIDTH
SUBTRACT 6" (152) FROM OVERALL WIDTH
|
| 3" |
|
|
| 223/4" |
|
| 3" |
|
|
(76) | (578) |
|
| (76) |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
OVERALL WIDTH
13/8" (35)
12" (305)
OVERALL
HEIGHT
12"
(305)
4" (102)
221/2" (572)
OVERALL DEPTH
Electrical Supply | 110/120 V AC, 60 Hz |
| 15 amp circuit |
Shipping Weight | |
(shell only) |
|
*Blower options vary with the size of hood
Unit dimensions may vary to ± 1/8" (3).
I N S T A L L A T I O N S P E C I F I C A T I O N S
Pro Hood Liners
and cooking surface. Refer to the Pro ventilation recommendations on pages
D E C O R A T I V E H O O D
A decorative hood can be created out of wood, plaster, tile or metal. The shape of the decorative hood is not critical. The only place where the liner and outside cover must meet is at the bottom edge of the metal liner. The decorative hood and liner must fit at the bottom edge in both width and depth.
The height of the liner does not have to be the same as the height of the decorative hood and is generally shorter.
The top depth of the liner, which is 12"
(305)standard, must be less than the interior depth of the decorative hood. Measure the interior depth of the hood at the top height of the liner to make sure the liner will fit inside the decorative hood.
The hood liner comes standard with a 4"
(102)lower reveal. Be sure to include this dimension in your decorative hood selec- tion.
Always use the interior measurements of the decorative hood and measure in multiple places. Use the smallest dimen- sions to verify hood liner specifications.
Dimensions in parentheses are in millimeters unless otherwise specified.
LOCATION OF ELECTRICAL | 6" | E |
| (152) | |
DECORATIVE HOOD |
| 5" |
| (127) | |
HOOD LINER |
|
|
WIDTH OF LINER |
|
|
30" TO 36"
TO COUNTERTOP
DECORATIVE HOOD |
|
12" (305) | HOOD LINER |
HEIGHT OF LINER |
|
30" TO 36" | 221/2" (572) |
DEPTH OF LINER | |
TO COUNTERTOP |
|
110