![](/images/new-backgrounds/1084715/8471527x1.webp)
I N S T A L L AT I O N O P T I O N S
The Wolf E Series double oven may be installed in combination with a Wolf warming drawer. Refer to the warming drawers section for specifications.
IMPORTANT NOTE: Unless you are using cabinets deeper than 24" (610) for a standard installation or 25" (635) for a flush inset instal-
E S E R I E S B U I L T - I N O V E N S
I N S T A L L AT I O N S P E C I F I C AT I O N S
E Series Built-In Double Oven
Flush Inset Installation
TOP VIEW |
|
24"min | 25"min |
(610) | (635) |
OPENING | FLUSH |
DEPTH | INSET |
| DEPTH |
1" (25) |
|
lation, it is recommended that the electrical supply be placed in an adjacent cabinet within reach of the conduit. Choose the location shown in the illustration that best suits your installation.
7/8" (22)
SIDE VIEW
495/8" |
| 5015/16" |
| ||
(1260) |
| min (1294) | |||
OPENING | FLUSH | ||||
HEIGHT | INSET | ||||
|
|
| HEIGHT | ||
|
|
| |||
|
|
|
| 67"typical | |
|
|
|
| (1702) | |
|
|
|
|
|
|
|
|
|
|
|
|
7/16" (11)
36" (914)
RECOMMENDED CABINET WIDTH
33"min (838) | E |
|
281/2" (724)
OPENING WIDTH
303/8"min (772)
FLUSH INSET WIDTH
ELECTRICAL LOCATION | 4" | |
WITHIN OPENING |
| |
APPLIES ONLY TO |
| (102) |
|
| |
CABINETS DEEPER | 5" | E |
THAN 25" (635) | ||
| (127) |
|
E
E
For flush inset installations, cabinet materials must be able to withstand temperatures up to 195˚F (90˚C) to avoid damage from high temperatures during
Dimensions in | Refer to installation |
parentheses are in | instructions shipped |
millimeters unless | with each Wolf |
otherwise specified. | product for detailed |
| specifications. |
14