![](/images/new-backgrounds/1084715/84715217x1.webp)
W O L F P R O V E N T I L A T I O N
W O L F P R O H O O D L I N E R S
Wolf Pro hood liners allow you to incorporate superior ventilation within your kitchen design. Whether you prefer French country or modernist, the Pro hood liners take care of the interior design, with true superior ventilation. All you have to do is decide what it will look like.
Sometimes referred to as power packs, these liners bring all the controls, lighting and conven- ience of our new ventilation line for those appli- cations with a custom exterior treatment.
Wolf Pro hood liners are recommended for use with all Wolf cooking appliances and are avail- able to accommodate 36" (914), 42" (1067), 48" (1219), 54" (1372) and 60" (1524) wide hoods.
F E A T U R E S
Stainless steel enclosed liner with seamed construction
Internal,
Recessed
Infinite-speed blower control
Heat sentry feature automatically turns unit on when heat is sensed and automatically adjusts blower speed
Halogen lighting with two settings
Removable,
Transition with backdraft damper included
M O D E L O P T I O N S
Pro Hood Liners
For 36" (914) Hood | PL342212 |
For 42" (1067) Hood | PL402212 |
For 48" (1219) Hood | PL462212 |
For 54" (1372) Hood | PL522212 |
For 60" (1524) Hood | PL582212 |
P L A N N I N G I N F O R M A T I O N
Pro hood liners are available to accommodate 36" (914), 42" (1067), 48" (1219), 54" (1372) and 60" (1524) wide hoods.
The ventilation hood should be at least as wide
as the cooking surface. It is recommended that Pro Hood Liner the hood overlap the cooking surface by 3" (76)
on either side.
Installation of all Pro hood liners should be 30" (762) to 36" (914) from the bottom of the decorative hood to the countertop.
The specifications provide overall dimensions and installation specifics for Pro hood liners. Refer to pages
E L E C T R I C A L R E Q U I R E M E N T S
Wolf Pro hood liners require a separate, grounded 120 V AC, 60 Hz power supply. The service should have its own 15 amp circuit breaker. Placement of the electrical supply is not critical, as long as you provide enough 120 V AC power cable to make your electrical connections.
Locate electrical within the shaded area shown in the Installation Specifications illustration.
IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation.
You must follow all National Electrical Code regulations. In addition, be aware of local codes and ordinances when installing your service.
A C C E S S O R I E S
Pro Hood Liners
38" (965) high classic stainless steel backsplash with or without warming racks
Accessories are available through your Wolf dealer. To obtain local dealer information, visit the Showroom Locator section of our website, wolfappliance.com.