FORMS DESCRIPTION LANGUAGE

Assuming that the upper left corner of the first box above is located two grid units down from the form origin and one grid unit to the right of the form origin, you would use the following statements:

TEXT IN BOX 2,1 `A:

IN NEXT BOX `B`

IN NEXT BOX 'C'

IN NEXT VERTICAL BOX 'D';

or

TEXT IN BOX 2,1 `A`

BOX `B`

BOX 'C'

VERTICAL BOX 'D';

The results of either statement are shown in figure 2-4.

Figure 2-4.Placing text in adjacent boxes

 

A

B

C

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

LOGO

 

 

 

 

 

 

 

Use this command to place .LGO files. A complex figure called a

 

logo up to two square inches in size can be digitized to order by

 

the Xerox Font Center or Rank Xerox. This logo is a special font

 

of one or more characters, which carries with it the relative

 

position of the characters that make up the logo. Thus, while a

 

logo may be made up of many characters, it is positioned as a

 

single unit. For additional flexibility, a signature may be digitized

 

and stored on the system as a logo.

Syntax

LOGO id AT y unit x unit;

Parameter options

id

 

 

 

 

The logo identifier (one to six characters).

y

Coordinate on the y axis where the logo origin is to be located.

unit

Unit of linear measurement, expressed as inches (IN), centimeters (CM), or DOTS. If units are not specified, the measurement is in grid units.

x

Coordinate on the x axis where the logo origin is to be located.

Example LOGO EAGLE AT 10,12;

Logo origin

XEROX 4050/4090/4450/4650 LPS FORMS CREATION GUIDE

2-17

Page 39
Image 39
Xerox 4650, 4450 manual Logo id AT y unit x unit