(CLP-370/340)/ (CLP-S308/S306, CLP-330)

Panel/Status Transmit

This function causes all the current instrument panel settings (selected voice, etc.) to be transmitted via the MIDI OUT terminal.

TERMINOLOGY

Setup Data:

Data that contains a set of panel settings for the Clavinova.

Procedure

1.Set up the panel controls as desired.

2.Connect the Clavinova to a sequencer via MIDI, and set up the sequencer so it can receive the setup data.

3.Engage the Function mode and select (CLP-

370/340)/ (CLP-S308/S306, CLP-330).

4.Press the [+/YES] button to transmit the panel/status data.

will appear on the LED display when the data has been successfully transmitted.

NOTE

For a list of the “Panel Data Contents” transmitted by this function, refer to our manual library at the following website. http://www.yamaha.co.jp/manual/

NOTE

Receiving the transmitted data:

1.Connect the Clavinova via MIDI to the device to which the setup data was transmitted previously.

2.Start sending the setup data from the device.

The Clavinova automatically receives the setup data, which will be reflected in the panel settings.

(For the data to be accepted, the Clavinova that receives the setup data should be the same model as the one that transmitted the setup data to the sequencer.)

NOTE

For more information on transmitting and receiving setup data via MIDI, refer to the owner’s manual for the connected MIDI device.

Detailed Settings – [FUNCTION]

(CLP-370/340)/ (CLP-S308/S306, CLP-330)

Initial Setup Send

This function lets you send the data of the panel settings to a computer. By transmitting the panel settings and recording them on the MIDI sequence recorder prior to the actual performance data, the instrument will be automatically restored to the same settings when the performance is played back. You can also use this function to change the settings of a connected tone generator to the same settings as the instrument.

Procedure

1.

Set up the panel controls as desired.

 

 

2.

Connect the Clavinova to a sequencer via MIDI, and

ENGLISH

 

370/340)/

 

(CLP-S308/S306, CLP-330).

 

 

set up the sequencer so it can receive the setup data.

 

3.

Engage the Function mode and select

 

 

(CLP-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.

Press the [+/YES] button to transmit the panel/status

 

 

data.

 

 

 

 

 

 

 

 

 

 

 

 

 

will appear on the LED display when the data has been successfully transmitted.

The following data can be sent.

Voice selection

[REVERB] type

[REVERB] depth

[EFFECT] type

[EFFECT] depth

Split point

Tuning (F1)

Dual detune (F3.2)

CLP-370/340/330, CLP-S308/S306 Owner’s Manual