SCSI Connection Set Up

Parity Check

The parity check is used for error correction during data transmissions. If parity- checking has to be disabled, the shunt on the Parity jumper switch should be removed.

Parity ON (Default)

Normally leave this setting alone.

ID SELECT

￿AR￿TY TERMINATOR

Parity OFF

ID SELECT

￿AR￿TY TERMINATOR

1 2 4

BLOC￿ SI￿E

1 2 4

BLOC￿ SI￿E

The setting allows for the parity

The setting does not

checking. Normally, set PARITY

allow for parity

to ON to enable error correction.

checking.

Note

By factory default, the Parity switch is set to “ON” and should normally be left in this state.

Termination

Terminators prevent SCSI signals from being reflected off the last device in the chain. The SCSI terminator switch should be set to “ON” if the CRW2200S is the last device on the internal SCSI chain. If the CRW2200S is not the last device on the internal SCSI chain, the shunt on the Terminator jumper switch should be removed.

 

Computer

Hard disk drive

 

(unterminated)

CRW2200S

 

 

(terminated)

MO drive

(terminated)

SCSI card

Terminator