Configuration
Configuration and Calibration Sequence
Display Shows | Action/Explanation |
|
|
CALIBRATING | The printer automatically adjusts the scale (gain) of the |
PLEASE WAIT | signals it receives from the media and ribbon sensors based |
| on the specific media and ribbon combination you are using. |
| On the sensor profile, this corresponds to moving the graph |
| up or down to optimize the readings for your application. |
RELOAD ALL | When RELOAD ALL is displayed: |
| Open the printhead and pull the media forward until a label |
| is positioned under the media sensor. |
| Move the ribbon back to its proper position. |
| Close the printhead. |
MEDIA AND RIBBON | Now that the scale has changed, the printer performs another |
CALIBRATE | calibration. During this process, the printer checks the |
| readings for the media and ribbon based on the new scale |
| you have established, determines the label length, and |
| determines whether you are in Direct Thermal or Thermal |
| Transfer Print Mode. The process is now complete. To see |
| the new readings on the new scale, print a sensor profile. See |
| illustration below. |
| Press SELECT to accept the calibration. |
| Press Plus (+) to go to the next display. |
|
|
70 | Z4Mplus and Z6Mplus User Guide |