Routine Care and Adjustments

Cleaning Procedures

Cleaning Procedures

Specific cleaning procedures are provided on the following pages. Below is a recommended cleaning schedule.

Area

 

Method

Printhead

 

Solvent*

Platen roller

Solvent*

Media sensors

Air blow

Ribbon sensor

Air blow

Media path

Solvent*

Ribbon path

Solvent*

Pinch roller. (Optional peel-

Solvent*

off option required. Refer to

 

page 92.)

 

 

Cutter

If cutting

Solvent*

Module

continuous,

 

 

pressure-sensitive

 

 

media

 

 

If cutting tag stock

Solvent*

 

or label liner

and air

 

material

blow

Tear-off/peel-off bar

Solvent*

Take label sensor

Air blow

.

IntervalDirect Thermal Mode: After every roll of media (or 500 feet of fanfold media).Thermal Transfer Mode: After every roll of ribbon or three rolls of media.

These intervals are intended as guidelines only. You may have to clean more often, depending upon your application and media.

After every roll of media (or more often, depending upon your application and media).

After every two or three rolls of media.

Once a month.

Once every six months.

*Zebra recommends using the Preventive Maintenance Kit, Part Number 47362 or a solution of 90% Isopropyl and 10% deionized water)

Note • Zebra Technologies Corporation will not be responsible for damage caused by the use of cleaning fluids on the Z4Mplus/Z6Mplus printer.

86