Troubleshooting

Print Quality Problems

Calibration

Problem

Loss of printing registration on labels. Excessive vertical drift in top-of-form registration.

Auto Calibrate failed.

Solution

Adjust the reflective sensor position. See page 26.

Set the printer for the correct media type. See page 63.

Ensure that the media guides are properly positioned.

Via the front panel, locate the SENSOR SELECT menu item (page 64) and manually select the correct sensing method.

Reload the media. Check the reflective sensor position (see page 26).

Clean the platen roller according to the instructions on page 87.

Perform a manual calibration (see page 69).

Reload the media and ensure the reflective sensor is properly positioned

(see page 26).

Z4Mplus and Z6Mplus User Guide

105