Communication

System Considerations

Printer Computer

36-pin

PC

male

 

25-pin

 

female

25-pin male

10 ft. (3 mm) maximum

Cable Requirements

Note • Zebra printers comply with FCC Rules and Regulations, Part 15 for Class B equipment using fully shielded data cables. Use of unshielded cables may increase radiation above the Class B limits.

Data cables must be fully shielded and fitted with metal or metalized connector shells. Shielded cables and connectors are required to prevent radiation and reception of electrical noise.

To minimize electrical noise pickup in the cable:

Keep data cables as short as possible.

Do not bundle the data cables tightly with the power cords.

Do not tie the data cables to power wire conduits.

Note • RS-422 and RS-485 applications should use twisted shielded pairs as recommended in the Appendix of the TIA/EIA-485 Specification.

32

Z4Mplus and Z6Mplus User Guide