Configuration

Configuration and Calibration Sequence

Display Shows

Action/Explanation

 

 

DELIMITER CHAR

Press SELECT to make change.

 

Delimiter Character: Press MINUS () to move to the next

 

digit position, press PLUS (+) to increase the value of the

 

digit.

 

Default: 2C (comma)

 

Range: 00 to FF

 

Press SELECT to accept the change.

 

The delimiter character is a 2-digit hex value used as a

 

parameter place marker in

 

ZPL/ZPL II format instructions. See the ZPL II

 

Programming Guide Volume I for more information.

Selecting ZPL Mode

 

ZPL MODE

Press SELECT to make change.

 

Selecting ZPL Mode: Press PLUS (+) or MINUS () to

 

display other choices.

 

Default: ZPL II

 

Selections: ZPL II, ZPL

 

Press SELECT to accept the change.

 

The printer remains in the selected mode until it is changed

 

by this front panel instruction or by using a ZPL/ZPL II

 

command. The printer accepts label formats written in either

 

ZPL or ZPL II. This eliminates the need to rewrite any ZPL

 

formats you already have. See the ZPL II Programming

 

Guide Volume II for more information on the differences

 

between ZPL and ZPL II.

 

 

76