Configuration
Configuration and Calibration Sequence
Display Shows | Action/Explanation |
| |
MEDIA POWER UP | Press SELECT to make change. |
| Media Power Up: Press PLUS (+) or MINUS |
| other choices. |
| Default: Calibration |
| Selections: Calibration, length, no motion, and feed |
| Press SELECT to accept the change. |
| This parameter establishes the action of the media when the |
| printer is turned on. |
| Calibration: Recalibrates the media and ribbon sensors. |
| Feed: Feeds the label to the first web. |
| Length: Determines the length of the label. |
| No Motion: Media does not move. |
HEAD CLOSE | Press SELECT to make change. |
| Head Close: Press PLUS (+) or MINUS |
| choices. |
Default: Calibration
Selections: Calibration, length, no motion, and feed
Press SELECT to accept the change.
Determines the action of the media after the printhead has been opened and then closed.
Calibration: Recalibrates the media and ribbon sensors.
Feed: Feeds the label to the first web.
Length: Determines the length of the label.
No Motion: Media does not move.
Z4Mplus and Z6Mplus User Guide | 77 |