Configuration

Configuration and Calibration Sequence

Display Shows

Action/Explanation

 

 

Setting Communication Parameters

Communication parameters must be set correctly for the printer to communicate with the host computer. These parameters make sure that the printer and host computer are speaking the same language. All communication parameters are password protected.

PARALLEL COMM

Press SELECT to make change.

 

Setting Parallel Communications: Press PLUS (+) or

 

MINUS () to display other choices.

 

Default: Bidirectional

 

Selections: Bidirectional, Unidirectional

 

Note • Unidirectional will not support ZNet two-way

 

communications.

 

Press SELECT to accept the change.

SERIAL COMM

Press SELECT to make change.

 

Setting Serial Communications: Press PLUS (+) or

 

MINUS () to display other choices.

 

Default: RS-232

 

Selections: RS-232, RS-422/485, RS-485 multidrop

 

Press SELECT to accept the change.

 

Select the communications port that matches the one being

 

used by the host computer.

BAUD

Press SELECT to make change.

 

Setting Baud: Press PLUS (+) or MINUS () to display

 

other choices.

 

Default: 9600

 

Selections: 110, 300, 600, 1200, 2400, 4800, 9600, 14400,

 

19200, 28800, 38400, 57600, 115200

 

Press SELECT to accept the change.

 

The baud setting of the printer must match the baud setting

 

of the host computer for accurate communications to take

 

place. Select the value that matches the one being used by

 

the host computer.

 

 

Z4Mplus and Z6Mplus User Guide

71